Results parameter Selected values in CT machine Bicondylar width BCoW in mm Body length BCrW in mm Ramus right with (WRMH) in mm Ramus left with (WLMH) in mm Actual Dimensions Measured with vernier 96.6293.2923.8523.45 Matrix Size256X25695.5893.1023.1622.12 512X51296.6093.1523.7223.33 1024X102496.8193.5024.2123.87 Layer Thickness0.6 mm96.4292.9023.1523.11 1 mm94.5591.1021.4821.35 5 mm 93.1190.1120.6720.39 Interval Thickness 0.6 mm96.2292.7023.2423.12 1 mm93.5191.1220.5421.11 5 mm 91.1290.2619.3819.73 Field of View30 cm96.4592.1023.1222.84 10 cm96.5893.1523.6523.12 threshold value in MIMICS software 220 HU94.1291.2121.1121.21 226 HU96.1193.1223.1521.10 230 HU98.2196.5725.6925.19 14